HOMEPRODUCTSCUSTOMIZED CABLES

 

 

Customized Products

Fire Resistant CAT6A SWB Armoured Data Cables

Fire Resisting S/FTP Cat6A Cable to IEC 60331-23

part no. FFX-CAT6S/FTP4P23FR SWB

 

 

 

 

Fire Resistant CAT6A SWB Armoured Data CablesFire Resistant CAT6A SWB Armoured Data Cables

Application:

Cat6 Cable is a cable standard for Gigabit Ethernet and other network protocol, suitable for 10BaseT, 100BaseTx & 1000BaseT (Gigabit Ethernet) application. In addition, these cables can  be  offered  with copper wire braid armoured & fame retardant outer sheath, providing additional mechanically protection still maintaining the fexibility of the cable.

STANDARDS:

Basic design adapted to EN 50173

FIRE PERFORMANCE£º

Circuit Integrity

IEC 60331-23; BS 6387 CWZ (Optional)

Flame Retardance (Single vertical wire or cable test)

IEC 60332-1-2; EN 60332-1-2

Reduced Fire Propagation (Vertically-mounted bundled wires & cables test)

IEC 60332-3-24; EN 60332-3-24

Halogen Free

IEC 60754-1; EN 50267-2-1

No Corrosive Gas Emission

IEC 60754-2; EN 50267-2-2

Minimum Smoke Emission

IEC 61034-2; EN 61034-2

CABLE CONSTRUCTION£º

Conductors: 23AWG solid bare copper.

Insulation: HDPE+fire barrier insulation.

Twinning: Two coloured insulated conductors twisted together to form a pair.

Individual Shield: Every pair is separately shielded with polyester aluminum foil, which covers> 100% of twisted pair, tinned copper drain wire is outside the Aluminum side contact with the braiding.

Fire Barrier tape: Mica glass tape applied over each pair. Overall Shield: Tinned copper braiding, min. 60% coverage.

Inner Sheath: Thermoplastic LSZH compound, coloured black. Armouring: Steel wire braiding.

Outer Sheath: SHF mud. Halogen-free fame retardant thermosetting LSZH compound type LTS3 as per BS 7655-6.1, which is  UV resistance, oil resistance, mud resistance.

PHYSICAL AND THERMAL PROPERTIES£º

Temperature range: -30°C - +75°C

Minimum bending radius during installation (mobile state): 8 x Overall Diameter

Minimum bending radius during operation (ixed state): 4 x Overall Diameter

ELECTRICAL PROPERTIES£º

AWG

 

23

Nominal Conductor Diameter

mm

0.58

Maximum DC Resistance@20°C

O/100m

9.38

Maximum DCR Unbalance

%

3

Maximum Mutual Capacitance

pF/m

5.8

Maximum Capacitance Unbalance

pF/100m

30

Characteristic Impedance@1-100MHz

O

100±15

Maximum Propagation Delay Skew

ns/100m

18

TRANSMISSION PROPERTIES£º

FREQ
MHz
Attenuation dB/100m NEXT
dB
PSNEXT
dB
ELFEXT
dB/100m
PSELFEXT
dB/100m
RL
dB

0.772

1.8

76.0

74.0

70.0

67.0

1

2.0

74.3

72.3

67.8

64.8

20.0

4

3.8

65.3

63.3

55.7

52.7

23.0

8

5.3

60.8

58.8

49.7

46.7

24.5

10

6.0

59.3

57.3

47.8

44.8

25.0

16

7.6

56.3

54.3

43.7

40.7

25.0

20

8.5

54.8

52.8

41.7

38.7

25.0

25

9.5

53.3

51.3

39.8

36.8

24.3

31.25

10.7

51.9

49.9

37.9

34.9

23.6

62.5

15.4

47.4

45.4

31.8

28.8

21.5

100

19.8

44.3

42.3

27.8

24.8

20.1

155

25.2

41.5

39.5

23.9

20.9

18.8

200

29.0

39.8

37.8

21.7

18.7

18.0

250

32.8

38.3

36.3

19.8

16.8

17.3

CONSTRUCTION PARAMETERS£º

Cable Code Construction
No. of Elements×No. of Cores in Element×Conductor Diameter
Nominal Insulation Thickness Nominal Inner Sheath Thickness Nominal Outer Sheath Thickness Approx. Overall Diameter Nominal Weight
  mm mm mm mm mm kg/km

FFX-CAT6S/FTP4P23FR SWB

4×2×0.58

0.45

0.9

1.1

20.0

530